LFP 51.2V100Ah battery for Portable 5000W Solar Generator Mobile Power Station
- Output power 5000W
- Capacity:5120Wh
- Parallel multiple Li-ion battery for more power, up to 50KWh(Max.10 sets in parallel)
- Input voltage: AC110/220V or customized (Global)
- Output voltage: DC5V AC110/220V or customized (Global)
- Wave pattern: Pure Sine Wave output
Inverter Parameters Specifications |
||
Specifications |
DC48V-AC220V |
|
Inverter specifications |
5KW |
|
Controller specifications |
60A |
|
Rated Voltage |
DC48V/AC220V; |
DC48V/AC110V; |
Operating Voltage Range (Normal Operating Battery Voltage) |
40.0V-62.0V (DC48V Power Supply) |
40.0V-62.0V (DC48V Power Supply) |
Low Voltage (beep alarm to alert users when battery's voltage is too low) |
42.0Vdc ± 1.0Vdc (48V Power Supply) |
42.0Vdc ± 1.0Vdc (48V Power Supply) |
Low Voltage Shut off(shut off when battery's voltage is too low) |
40.0Vdc ± 1.0Vdc (48V Power Supply) |
40.0Vdc ± 1.0Vdc (48V Power Supply) |
Low Voltage Recovery (Automatic Boot when battery's voltage returns to normal) |
48.0Vdc ± 0.3Vdc (48V Power Supply) |
48.0Vdc ± 0.3Vdc (48V Power Supply) |
High Voltage Alarm and shut off (beep alarms and shut off when the battery's voltage is over high) |
64.0Vdc ± 1.0Vdc (48V Power Supply) |
64.0Vdc ± 1.0Vdc (48V Power Supply) |
High Voltage Recovery (Automatic boot when battery's voltage returns to normal) |
60.0Vdc ± 1.0Vdc (48V Power Supply) |
60.0Vdc ± 1.0Vdc (48V Power Supply) |
Inverter Efficiency |
≥90% |
≥90% |
DC-priority type,battery low voltage conversion point when there is utility electricity(turn to utility electricity to supply when battery is lower than these) |
44Vdc ± 1.2Vdc (48V Power Supply) |
44Vdc ± 1.2Vdc (48V Power Supply) |
DC-priority type,battery low voltage recovery point after turning to utility electricity to supply,(turn to battery to supply electricity when the battery's voltage is higher than these) |
54.0Vdc ± 1.2Vdc (48V Power Supply) |
54.0Vdc ± 1.2Vdc (48V Power Supply) |
AC Input Specifications |
||
Rated Voltage Specifications |
220VAC System |
110VAC System |
Input Voltage Waveform |
Pure Sine wave (utility electricity or generator) |
Pure Sine wave (utility electricity or generator) |
Rated Input Voltage |
220Vac/230Vac/240Vac |
110Vac/120Vac/130Vac |
Low Voltage Shut off |
180Vac±4% |
85Vac±4% |
Low Voltage Recovery |
195Vac±4% |
90Vac±4% |
High Voltage Shut off |
260Vac±4% |
135Vac±4% |
High Voltage Recovery |
255Vac±4% |
130Vac±4% |
Charging rules of Utility Electricity |
Three stages |
|
Constant current charging(constant current stage)→constant voltage (constant voltage stage)→float(constant voltage stage) |
||
Utility Electricity Supply Efficiency |
≥98% |
|
Conversion time(AC to DC) |
<4ms |
|
Conversion time(DC to AC) |
<8ms |
|
AC Output Specifications |
||
Rated Output Voltage(V) |
220Vac/230Vac/240Vac |
110Vac/120Vac/130Vac |
Output Voltage Range |
±10%rms |
|
Rated output frequency(Hz) |
50Hz±0.3Hz/60Hz±0.3Hz(optional) |
|
Power Factor |
1 |
|
Output Wave Form |
Pure Sine Wave |
|
Waveform distortion rate(THD) |
≤3%(Linear load) |
|
Dynamic Response(0~100%) |
5% |
|
Peak Factor(CF) |
3:1 |
|
Overload Protection (SMPS load) |
(110%<Load125%)±10%: disconnecting the output voltage after 15 minutes (125%<Load<150%)±10%: disconnecting the output voltage after 1 minutes (Load>150%)±10%: disconnecting the output voltage after 20 seconds |
|
Battery Parameters |
||
Cell |
LFP |
|
Specification |
51.2V/100Ah |
|
Output Power |
5KW |
|
Charging Current |
100A sustained Max. |