Portable 5000W Solar Generator Mobile Power Station
- Output power 5000W
- Built-in battery: 51.2V 100Ah - 5120Wh LFP Battery
- Parallel multiple Li-ion battery for more power, up to 50KWh(Max.10 sets in parallel)
- Input voltage: AC110/220V or customized (Global)
- Output voltage: DC5V AC110/220V or customized (Global)
- Product accessories: AC Power Wire, Solar DC Charging Line, Instruction Manual
- Battery model: Polymer pouch cell 93133202LFP
- Wave pattern: Pure Sine Wave output
- Applicaiton: Household Appliances, Outdoor Camping, Barbecue, Self-driving Tour, Emergency, etc.
Product Details
Portable 5000W Solar Generator Mobile Power Station |
||
Inverter Parameters Specifications |
||
Specifications |
DC48V-AC220V |
|
Inverter specifications |
5KW |
|
Controller specifications |
60A |
|
Rated Voltage |
DC48V/AC220V |
DC48V/AC110V |
Operating Voltage Range(Normal Operating Battery Voltage) |
40.0V-62.0V (DC48V Power Supply) |
40.0V-62.0V (DC48V Power Supply) |
Low Voltage(beep alarm to alert users when battery's voltage is too low) |
42.0Vdc ± 1.0Vdc (48V Power Supply) |
42.0Vdc ± 1.0Vdc (48V Power Supply) |
Low Voltage Shut off(shut off when battery's voltage is too low) |
40.0Vdc ± 1.0Vdc (48V Power Supply) |
40.0Vdc ± 1.0Vdc (48V Power Supply) |
Low Voltage Recovery(Automatic Boot when battery's voltage returns to normal) |
48.0Vdc ± 0.3Vdc (48V Power Supply) |
48.0Vdc ± 0.3Vdc (48V Power Supply) |
High Voltage Alarm and shut off(beep alarms and shut off when the battery's voltage is over high) |
64.0Vdc ± 1.0Vdc (48V Power Supply) |
64.0Vdc ± 1.0Vdc (48V Power Supply) |
High Voltage Recovery(Automatic boot when battery's voltage returns to normal) |
60.0Vdc ± 1.0Vdc(48V Power Supply) |
60.0Vdc ± 1.0Vdc(48V Power Supply) |
Inverter Efficiency |
≥90% |
≥90% |
DC-priority type,battery low voltage conversion point when there is utility electricity (turn to utility electricity to supply when battery is lower than these) |
44Vdc ± 1.2Vdc (48V Power Supply) |
44Vdc ± 1.2Vdc(48V Power Supply) |
DC-priority type,battery low voltage recovery point after turning to utility electricity to supply, (turn to battery to supply electricity when the battery's voltage is higher than these) |
54.0Vdc ± 1.2Vdc(48V Power Supply) |
54.0Vdc ± 1.2Vdc(48V Power Supply) |
AC Input Specifications |
||
Rated Voltage Specifications |
220VAC System |
110VAC System |
Input Voltage Waveform |
Pure Sine wave(utility electricity or generator) |
Pure Sine wave(utility electricity or generator) |
Rated Input Voltage |
220Vac/230Vac/240Vac |
110Vac/120Vac/130Vac |
Low Voltage Shut off |
220Vac/230Vac/240Vac |
110Vac/120Vac/130Vac |
Low Voltage Shut off |
180Vac±4% |
85Vac±4% |
Low Voltage Recovery |
195Vac±4% |
90Vac±4% |
High Voltage Shut off |
260Vac±4% |
135Vac±4% |
High Voltage Recovery |
255Vac±4% |
130Vac±4% |
Charging rules of Utility Electricity |
Three stages |
|
Constant current charging(constant current stage)→constant voltage(constant voltage stage)→float(constant voltage stage) |
||
Utility Electricity Supply Efficiency |
≥98% |
|
Conversion time(AC to DC) |
<4ms |
|
Conversion time(DC to AC) |
<8ms |
|
AC Output Specifications |
||
Rated Output Voltage(V) |
220Vac/230Vac/240Vac |
110Vac/120Vac/130Vac |
Output Voltage Range |
±10%rms |
|
Rated output frequency(Hz) |
50Hz±0.3Hz/60Hz±0.3Hz(optional) |
|
Power Factor |
1 |
|
Output Wave Form |
Pure Sine Wave |
|
Waveform distortion rate(THD) |
≤3%(Linear load) |
|
Dynamic Response(0~100%) |
5% |
|
Peak Factor(CF) |
'3:1 |
|
Overload Protection (SMPS load) |
(110%<Load125%)±10%:disconnecting the output voltage after 15 minutes
(125%<Load<150%)±10%:disconnecting the output voltage after 1 minutes
(Load>150%)±10%:disconnecting the output voltage after 20 seconds
|
|
Other notes |
||
Continuous operation time |
can continuous operation |
|
Comsuption when Normal Boot, no-load |
≤Rated Power×2.5% |
|
Comsuption of energy-saving mode |
≤6W |
|
Safety Certification |
CE(EN62040-1)EMC:EN62040-2,C2 |
|
Communication Interface |
RS232/(Customizable) |
|
Cooling |
Temperature-controlled variable speed cooling-fan(Ventilation condition) |
|
Noise(dB,1meter) |
<60dB |
|
operate temperature(℃) |
−10~+45 |
|
Storage Temperature(℃) |
−20~+55 |
|
Using Environment Humidity |
0~95% relative humidity(No condensation) |
|
Altitude(m) |
≤5000(more than 1000m, derating) |
|
Display Way |
LED lights + LCD screen |
|
Alarm Way |
Buzzer sounds alarm |
|
Protection Functions |
Low Voltage protection, high voltage protection, high temperature protection, short circuit protection, leakage protection, overcurrent protection, overload protection, low voltage recovery, high voltage recovery,intelligent temperature control, solid barrier alarm |
|
Protection Level |
IP20/Customizable |
|
Machine Dimension |
L625*W360*H610mm |
|
Total Weight |
about 81.2kg |
|
Parameter Specifications of Solar Charge Controller |
||
Specifications |
60A |
|
Items |
Controller Type |
MPPT |
MPPT Efficiency |
≥99.5% |
|
Quiescent Dissipation No-load |
0.5W~1.2W |
|
System Voltage |
Automatic identification |
|
Heat dissipation |
Air cooling |
|
Voltage Range System Identify |
DC42V~DC60V |
|
Input Characteristic |
PV open circuit voltage (VOC) |
DC150V |
Input Overvoltage Protection Voltage |
DC150V |
|
Input Overvoltage Recovery |
DC145V |
|
Solar Panel Rated Input Power |
3120W |
|
Charging Characteristic |
Battery |
lithium iron phosphate battery |
Charging Rated Current |
60A |
|
Ambient-temperature Compensation |
'-3mV/℃/2V(default) |
|
Charging mode |
Three stages:constant current(fast charging),constant voltage,float |
|
Output Voltage Accuracy |
≤±1.5% |
|
Load Characteristics |
On-load Voltage |
same as the battery voltage |
Rated Load Current |
60A |
|
Load Control Method |
Normally open or closed/Double period control/Optical control/Optical control plus Fixed period control |
|
Low-voltage Protection |
The default is 10.5V, the recovery is 11V(user set) |
|
Setting Mode |
Upper computer/APP/Controller interface |
|
Display / communications |
Display Mode |
HD LCD Segmented Backlight display |
Communication Mode |
RJ45(8p8c)/RS485/support Host control/Support WIFI to realize Cloud Monitoring via APP |
|
Additional Properties |
Protection Function |
Input/Output overvoltage/low-voltage protection, 、Reverse connect protection, Temperature protection, Battery drop protection, etc. |
Operating Temperature |
'-20℃~+50℃ |
|
Storage Temperature |
-40℃~+75℃ |
|
IP Level |
IP21 |
|
Noise |
≤40dB |
|
Altitude |
0~3000m |
|
Max.wrie size |
30mm2 |
|
Battery Parameters |
||
Specification |
LFP 51.2V/100Ah |
|
Output Power |
5KW |
|
Charging Current |
100A sustained Max. |
|
Charge via Utility Grid |
||
DC voltage level |
48V |
|
Charging current |
40A |
|
Breaker size |
30A |
|
Theoretical charge voltage |
56V |
|
Charging circuit protection |
Circuit breaker protection |
|
Charging rules |
Constant current charging(constant current stage)→constant voltage(constant voltage stage)→float(constant current stage) |
|
Charging-stage conversion |
►constant current charging stages:input AC grid, the charger will run until to the constant voltage of maximum rated current. ►constant voltage charging stage:The charger will keep the mode of constant voltage, then the voltage drops to float voltage. ►floating stage:at the floating stage, the voltage will keep the float voltage. ►If you re-connect the AC, the charger will recycle the steps of above when the battery voltage drops below 12Vdc. ►If the Chargers keep floating state for 10 days, the charger will restart the cycle. |
|
Inquiry Now
Can't find the specific information you’re looking for? Have a question ? Contact Us